Power Dividers and Combiners

DL201

Lumped element based circuit technology allows for a compact housing to be applied for all frequency bands offered. Design package accommodates SMA, N, BNC and TNC connectors. Design modification may be necessary for N connectors. 

FEATURES:

  • 50 Impedance Values
  • High Isolation
  • Low Loss
  • Standard SMA Connectors (N, BNC, TNC optional)

Finish: Chemical Conversion Coating per MIL-DTL-5541 Class 3 (optional paint available upon request)
Marking: All units supplied with P/N and date code on polyester label (special marking available upon request)
Electrical Test: All units tested on a Go/No-go basis (plotted data available upon request). Specifications indicated are subject to change. Unless otherwise specified, electrical properties correspond to use with standard SMA connectors.
Dimensions: All dimensions are expressed in inches, (1 inch = 25.4mm). All dimensions indicated are subject to change. Unless otherwise specified, tolerances for decimals are ±0.02 for .XX and ±0.005 for .XXX. Tolerances for angles are ±0°30'.
Temperature: Units designed to operate -55° to +85° C.

General Parameters:
Type: 2-WAY
Freq Range: 0.02-20 MHz
Low Frequency [MHz]: 0.02
High Frequency [MHz]: 20
Insertion Loss [dB]: 0.55
Isolation [dB]: 30
VSWR [:1]: 1.30:1
VSWR2: 1.30:1
Amplitude Balance [dB]: 0.1
Phase Balance [deg]: 1
Input Power [W]: 10

3D View

Download